Development Toner near empty
mode
e-STUDIO556/656/756/856
Item
Subitem
Code
5563
5568
5569
5576
5577
5581
5585
5810
Sub-
Default
Acceptable
Details
code
value
value
Setting value of PM
Refer to
8 digits
time counter display/0
content
clearing / Parts
Current value of PM
0
8 digits
counter Display/0
clearing
Current value of PM
0
8 digits
time counter
Current value of PM
0
8 digits
counter Display/0
clearing / Parts
Current value of PM
0
8 digits
time counter / Parts
Switching of output
0
0~2
pages/ driving counts
at PM
Switching of output
0
0~2
pages/ driving counts
at PM / Parts
Toner near-empty
3
1-99
status threshold value
setting (%)
34
RAM
Contents
M
Time accumulating counter
<Default value>
e-STUDIO556/656 :470,000
e-STUDIO756/856 :390,000
M
Counts up when the registration sensor is ON.
M
Counts the drum driving time.
M
Counts up when the registration sensor is ON.
M
Counts the drum driving time.
M
Selects the reference to notify the PM timing. (The
message is displayed on the LCD screen.)
0: PM counter (The number of output pages is set at
08-6190.)
1: PM time counter (The timing is set at 08-6191.)
2: Whenever either the PM counter or the PM time
counter has exceeded the threshold
M
Selects the reference to notify the PM timing. (The
message is displayed on the LCD screen.)
0: PM counter (The number of output pages is set at
08-6190.)
1: PM time counter (The timing is set at 08-6191.)
2: Whenever either the PM counter or the PM time
counter has exceeded the threshold
M
This code is used when the value of 08-5155 is set to
"4". Use this code to specify the threshold value (unit:
%) for displaying the toner near-empty status. The
accuracy of value is influenced by usage environment
or originals.
Proce