(13) Take off the fuser roller covering it with paper
and such not to make scars on it.
4.11.9
Pressure roller
(1)
Take off the fuser roller.
( P.4-123 "4.11.8 Fuser roller")
(2)
Take off the pressure roller with its bearing.
(3)
Remove 2 bearings and 2 collars from the
pressure roller.
Note:
Pay attention to the parts when taking off the
pressure roller because those for e-
STUDIO557 and e-STUDIO657/757/857 are
different.
The outside diameter of the pressure roller
- e-STUDIO557: ø50
- e-STUDIO657/757/857: ø60
4.11.10 Web detection sensor (S8)
(1)
Take off the fuser unit.
( P.4-115 "4.11.2 Fuser unit")
(2)
Take off the cleaning web unit.
( P.4-117 "4.11.3 Cleaning web unit /
Cleaning web")
(3)
Take off the fuser unit cover (front).
(4)
Disconnect 1 connector and remove 1 screw
to take off the web detection sensor with its
bracket.
(5)
Release the latch of the sensor to take off the
web detection sensor.
© 2011 - 2014 TOSHIBA TEC CORPORATION All rights reserved
Fig. 4-347
Fig. 4-348
Fig. 4-349
e-STUDIO556/656/756/856/557/657/757/857
4 - 125
Fuser roller
Pressure roller
Web detection sensor
Screw