Download Print this page

Toshiba e-STUDIO556 Service Manual page 190

Multifunctional digital systems
Hide thumbs Also See for e-STUDIO556:

Advertisement

Notes:
Do not touch 6 screws shown with the
arrows when replacing the lens unit.
* Red color screw.
Handle the unit with care. Do not touch
the adjusted area and lens. (Hold the unit
as the right figure.).
[B] Installation of lens unit
(1)
Attach the lens unit and fix it temporarily with
2 screws.
(2)
Match the center scale of the plate in which
the unit is to be installed and the rightmost
scale of the adjusting hole on the lens unit
plate.
e-STUDIO556/656/756/856/557/657/757/857
DISASSEMBLY AND REPLACEMENT
Screw
© 2011 - 2014 TOSHIBA TEC CORPORATION All rights reserved
4 - 26
Fig. 4-71
Fig. 4-72
[ Rear ]
[ Front ]
Fig. 4-73

Advertisement

loading