Tandem LCF
(1)
Remove the screw 1 on the left side of the Tandem LCF and the screw 2 on the right side, and
then temporarily fix it to the oblong hole. rescrew it to the oblong hole.
(2)
Loosen the screw 2 on the left side of the Tandem LCF and the screw 1 on the right side.
(3)
Remove screw 3, and then temporarily fix to the oblong hole.
(4)
Move the front cover of the Tandem LCF to the front or rear side, and then tighten screw 1 and 2.
(5)
Align the surface of the covers of the 2nd drawer and Tandem LCF. If they do not align, adjust the
angle of the Tandem LCF front cover.
(6)
Tighten screw 6.
1
2
3
Note:
When the sideways deviation has been adjusted for the Tandem LCF feeding, adjust its
protruding point.
If the Tandem LCF drawer cannot be closed securely, decrease the protruding amount.
(When the value decreases in increments of "1", the protruding amount decreases by 1 mm.)
(1) Move 2 screws of the bracket on the rear side in the same increments as the digit of the scale
at right on the front side.
(In case of No. 5, 6 and 7, place the bracket upside down to install it.)
Bracket
Screw
e-STUDIO556/656/756/856/557/657/757/857
ADJUSTMENT
( A )
Fig. 6-42
Protruded
distance
Max 7
Min 1
Fig. 6-43
6 - 56