e-STUDIO556/656/756/856
Item
Subitem
Transfer correction
Thick paper2
value
Transfer correction
Thick paper2
value
Transfer correction
Duplex printing
value
Transfer correction
Duplex printing
value
Transfer correction
Duplex printing
value
Transfer correction
Transparency
value
Transfer correction
Transparency
value
Transfer correction
Transparency
value
Transfer timing
Thick paper3
correction
Transfer timing
Thick paper3
correction
Sub-
Default
Code
Details
code
value
2930
1
C
106
2930
2
L
150
2931
0
H
128
2931
1
C
128
2931
2
L
128
2932
0
H
150
2932
1
C
106
2932
2
L
150
2960
Transfer timing
2
correction
2961
0
H
150
2961
1
C
106
10
Acceptable
RAM
Contents
value
0~255
M
The output value of the transfer bias at the center of the
paper is corrected.
0~255
M
The output value of the transfer bias at the trailing edge
of paper is corrected.
0~255
M
The output value of the transfer bias at the leading
edge of paper is corrected.
0~255
M
The output value of the transfer bias at the center of the
paper is corrected.
0~255
M
The output value of the transfer bias at the trailing edge
of paper is corrected.
0~255
M
The output value of the transfer bias at the leading
edge of paper is corrected.
0~255
M
The output value of the transfer bias at the center of the
paper is corrected.
0~255
M
The output value of the transfer bias at the trailing edge
of paper is corrected.
0~4
M
The timing to turn on the transfer bias is corrected.
<e-STUDIO556/656>
0: Approx. 8.2 mm passed from the reference position
1: Approx. 6.8 mm passed from the reference position
2: Approx. 5.4 mm passed from the reference position
3: Approx. 4.1 mm passed from the reference position
4: Turns on at the reference position
<e-STUDIO756/856>
0: Approx. 9.8 mm passed from the reference position
1: Approx. 8.2 mm passed from the reference position
2: Approx. 6.6 mm passed from the reference position
3: Approx. 4.9 mm passed from the reference position
4: Turns on at the reference position
0~255
M
0~255
M
Proce
Servic
dure
e UI
4
4
4
4
4
4
4
4
1
4
4

Advertisement