Download Print this page

Toshiba e-STUDIO556 Service Manual page 1165

Multifunctional digital systems
Hide thumbs Also See for e-STUDIO556:

Advertisement

Sub
05/08
Mode
Element
element
08
Setting
System
Initialization
Mode
08
Setting
System
All clearing
Mode
08
Setting
System
General
Mode
08
Setting
System
User interface
Mode
08
Setting
System
General
Mode
08
Setting
System
User interface
Mode
e-STUDIO556/656/756/856
Item
Subitem
LGC-SRAM board
Sub-
Default
Code
Details
code
value
9083
Initialization of NIC
-
information
9090
Printer all clear
-
9100
Date and time setting
-
9102
Date display format
Refer to
contents
9103
Time differences
Refer to
contents
9110
Auto-clear timer
3
setting
106
Acceptable
RAM
Contents
value
SYS Returns the value to the factory shipping default value.
-
M
Initializes the NVRAM (for LGC board).
13 digits
-
Year/month/date/day/hour/minute/second
Example: 03 07 0 13 13 27 48
"Day" - "0" is for "Sunday". Proceeds Monday through
Saturday from "1" to "6".
0~2
SYS 0: YYYY.MM.DD. 1: DD.MM.YYYY 2: MM.DD.YYYY
<Default value>
MJD: 1
JPC: 0
Others: 2
0~47
SYS 0: +12.0h 1: +11.5h 2: +11.0h 3: +10.5h 4: +10.0h 5:
+9.5h 6: +9.0h 7: +8.5h 8: +8.0h 9: +7.5h 10: +7.0h 11:
+6.5h 12: +6.0h 13: +5.5h 14: +5.0h 15: +4.5h 16:
+4.0h 17: +3.5h 18: +3.0h 19: +2.5h 20: +2.0h 21:
+1.5h 22: +1.0h 23: +0.5h 24: 0.0h 25: -0.5h 26: -1.0h
27: -1.5h 28 -2.0h 29: -2.5h 30: -3.0h 31: -3.5h 32: -
4.0h 33: -4.5h 34: -5.0h 35: -5.5h 36: -6.0h 37: -6.5h 38:
-7.0h 39: -7.5h 40: -8.0h 41: -8.5h 42: -9.0h 43: -9.5h
44: -10.0h 45: -10.5h 46: -11.0h 47: -11.5h
<Default value>
JPC: 6
NAD: 40
MJD: 24
Others: 0
0~10
SYS Timer to return the equipment to the default settings
when the [START] button is not pressed after the
function and the mode are set.
0: No limit (disabled) 1 to 10: Set number x 15 sec.
Proce
Servic
dure
e UI
3
Yes
3
Yes
5
1
1
1

Advertisement