Note:
When assembling the main charger, install it
so that the charger wire passes through the
center of the pad.
4.7.2
Wire cleaner drive unit / Wire cleaner drive motor (M12)
(1)
Take off the cleaner unit.
( P.4-75 "4.8.1 Cleaner unit")
(2)
Disconnect 1 connector, remove 1 screw,
and then take off the wire cleaner drive unit.
(3)
Disconnect 1 connector, remove 1 screw,
and then take off the wire cleaner drive motor
(M12) with the bracket.
(4)
Remove 2 screws and take off the wire
cleaner drive motor.
Note:
Pay attention to the size (length) of the
screws. If incorrect ones are used, the motor
could be damaged.
e-STUDIO556/656/756/856/557/657/757/857
DISASSEMBLY AND REPLACEMENT
Cleaning pad
Fig. 4-194
Charger guide
Cleaner unit
Fig. 4-195
Screw
Wire cleaner drive motor
Fig. 4-196
© 2011 - 2014 TOSHIBA TEC CORPORATION All rights reserved
4 - 70
Charger wire
Cleaning pad
Screw
Main charger
Screw