(3)
Release 2 latches and take off the original
reading start sensor.
Note:
When replacing the original reading start
sensor, be sure to perform the original
reading start sensor adjustment.
( P.6-80 "6.15.8 Original reading start
sensor adjustment")
4.13.54 Original reading start sensor (prism)
(1)
Take off the reading start guide unit.
( P.4-141 "4.13.10 Reading start guide
unit")
(2)
Remove 4 screws and take off the stay.
(3)
Remove 2 screws and take off the original
reading start sensor prism unit.
Note:
When replacing the original reading start
sensor, be sure to perform the original
reading start sensor adjustment.
( P.6-80 "6.15.8 Original reading start
sensor adjustment")