8.2.2
Service call
Error code
Classification
C130
Paper feeding
system related
service call
C140
C150
C160
C180
C1A0
C1C0
C260
Scanning system
related service call
C261
C262
C270
C280
C290
C360
Process related
service call
C370
e-STUDIO556/656/756/856/557/657/757/857
ERROR CODE AND TROUBLESHOOTING
Contents
1st drawer tray abnormality: The tray-up motor-1 does
not run normally or the 1st drawer tray does not move
normally.
(Feeding of any other drawer than the 1st drawer is
possible.)
2nd drawer tray abnormality: The tray-up motor-1 does
not run normally or the 2nd drawer tray does not move
normally.
(Feeding of any other drawer than the 2nd drawer is
possible.)
3rd drawer tray abnormality: The tray-up motor-2 does
not run normally or the 3rd drawer tray does not move
normally.
(Feeding of any other drawer than the 3rd drawer is
possible.)
4th drawer tray abnormality: The tray-up motor-2 does
not run normally or the 4th drawer tray does not move
normally.
(Feeding of any other drawer than the 4th drawer is
possible.)
Tandem LCF tray-up motor abnormality: The Tandem
LCF tray-up motor does not run normally or the Tandem
LCF tray does not move normally.
(Feeding of any other drawer than the Tandem LCF is
possible.)
Tandem LCF end fence motor abnormality: The Tandem
LCF end fence motor does not run normally or the
Tandem LCF end fence does not move normally.
(Feeding of any other drawer than the Tandem LCF is
possible.)
Option LCF tray-up motor abnormality: The Option LCF
tray-up motor does not run normally or the Option LCF
tray does not move normally.
(Feeding of any other drawer than the Option LCF is
possible.)
Peak detection error: Lighting of the exposure lamp
(white reference) is not detected when the power is
turned ON.
Peak detection error: Lighting over
(Only for e-STUDIO557/657/757/857)
Communication error has occurred between the CCD
board and the SYS board.
(Only for e-STUDIO557/657/757/857)
Carriage home position sensor not turning OFF within a
specified period of time: The carriages do not shift from
their home position within a specified period of time.
Carriage home position sensor not turning ON within a
specified period of time: The carriages do not reach their
home position within a specified period of time.
Scanner fuse blowout: 24V power for the scanning
system is not supplied at the scanner warming-up after
power-ON.
Wire cleaner drive motor abnormality: The wire cleaner
drive motor does not run normally or the charger wire
cleaner does not move normally.
Transfer belt cam motor abnormality: The transfer belt
cam motor does not run normally when the power is
turned ON or the copying is started.
8 - 12