Restart the equipment after the backup is completed. If you want to perform the backup of the
license, do not restart the equipment but perform from (4) in "[I] Backup license".
[I]
Backup license
Note:
If "3. License SRAM to FROM" is performed by mistake, carry out the following procedure.
 P.9-37 "[A] Re-registration when the board is replaced"
(1)
Turn the power ON while pressing [3] and the [C] button simultaneously.
(2)
Enter the password, and then press the [OK].
(If the password is not set for Service, press the [OK] button without entering anything.)
(3)
Key in [5] to select "5. Key Backup Restore", and then press the [START] button.
(4)
Key in [4] to select "4. License FROM to SRAM", and then press the [START] button.
(5)
Wait until the backup of the license is completed. "Operation Complete" is displayed.
(6)
Restart the equipment after the backup is completed.
(7)
Turn the power OFF.
[J]
Initialize SRAM board
(1)
Turn the power ON while pressing [0] and [8] simultaneously.
(2)
Enter the password, and then press the [OK].
(If the password is not set for Service, press the [OK] without entering anything.)
(3)
Initialize the SRAM error.
1. When "SRAM REQUIRES INITIALIZATION" is displayed on the LCD, check the destination
and then press the [START] button.
If the destination is not correct, key in the correct one and then press the [START] button.
2. After the confirmation message is displayed, press the [INTERRUPT] button.
(4)
Perform the panel calibration (08-9050).
1.Touch the center of "+" mark displayed on the upper left of the LCD.
2.Touch the center of "+" mark displayed on the upper right of the LCD.
3.Touch the center of "+" mark displayed on the lower left of the LCD.
4.Touch the center of "+" mark displayed on the lower right of the LCD.
(5)
Perform the initialization at the software version upgrade (08-9030).
(6)
Initialize the NIC information (08-9083).
(7)
Enter the serial number (08-9601).
Key in the serial number on the label attached to the rear cover of the equipment, and then press
the [OK].
(8)
Turn the power off.
[K] Reinstall license
If the license was returned in " P.9-28 "[B] Return License", reinstall it with the following procedure.
(1)
Turn the power ON while pressing [0] and [8] simultaneously.
(2)
Enter the password, and then press the [OK] button.
(If the password is not set for Service, press the [OK] button without entering anything.)
(3)
Key in [3840], and then press the [START] button.
(4)
Press the [INSTALL] button.
(5)
Install the one-time dongle in the equipment (the one which you used for returning the selected
license before replacing the equipment). Then press the [OK] button.
(6)
Select the license to be installed, and then press the [INSTALL] button.
(7)
The screen for notifying that the installation will be started is displayed. Then press the [YES]
button.