Chrysler 1997 Stratus Convertible RHD Service Manual page 616

Table of Contents

Advertisement

8W - 60 - 6
DESCRIPTION AND OPERATION (Continued)
Ground for the window motor is supplied on the
Q17 circuit. Circuit Q17 connects from the left rear
window motor to the master switch. A bus bar, inter-
nal to the switch, connects the Q17 circuit to the Z1
circuit. The Z1 circuit is terminated at the instru-
ment panel left side cowl.
For window UP operation the circuits are reversed.
Circuit Q17 is the feed, and circuit Q31 and circuit
Q27 are the ground.
RIGHT REAR WINDOW
When the DRIVER selects window DOWN opera-
tion power is supplied on the F21 circuit through the
switch to circuit Q32. Circuit Q32 connects from the
drivers door switch to the window timer module. The
power is passed though the normally CLOSED con-
tacts in the module to circuit Q28. Circuit Q28 con-
nects from the module to the motor.
Ground for the window motor is supplied on the
Q18 circuit. Circuit Q18 connects from the right rear
window motor to the master switch. A bus bar, inter-
nal to the switch, connects the Q18 circuit to the Z1
circuit. The Z1 circuit is terminated at the Instru-
ment Panel left side cowl.
For window UP operation the circuits are reversed.
Circuit Q18 is the feed, and circuit Q32 and circuit
Q28 are the ground.
POWER WINDOW OPERATION (W/POWER TOP
OPERATION)
NOTE: The power windows on this vehicle operate
automatically in the down mode when the power
8W - 60 POWER WINDOWS
top switch is activated. Refer to the following circuit
descriptions for operation in this mode. For regular
power window operation refer to the previous cir-
cuit description.
The power window system on this vehicle utilizes a
pair of external relays (2) and a window timer mod-
ule located in the left door to control the operation of
the windows when the power top is activated.
Power for the window timer module is supplied on
circuit P5 or P6. The F21 circuit supplies power for
the power window switches, and the contact side of
the power window relays. Ground for the module is
supplied on circuit Z1.
When the power top switch is activated circuit P6
for top UP, or P5 for top DOWN, sends a voltage sig-
nal to the window timer module. The window timer
module then provides voltage to the coil side of the
relays. This causes the normally OPEN contacts in
the relays to CLOSE connecting power to the DOWN
side of wach window motor. All windows then operate
in the DOWN mode for a pre-determined length of
time.
HELPFUL INFORMATION
• Check the 20 amp circuit breaker located in cav-
ity 19 of the junction block
• Check the 40 amp fuse located in cavity 18 of
the PDC
• Check for a good ground at the instrument panel
left side cowl
• Refer to the appropriate group of the Service
Manual for additional test procedures
JX

Advertisement

Table of Contents
loading

This manual is also suitable for:

1997 stratus convertible lhd

Table of Contents