Chapter 7 Maintenance Screens
Be sure to upload the correct model firmware as uploading the wrong
model firmware may damage a card.
Figure 106 FW Upgrade
The MSC supports dual firmware images, ras-0 and ras-1. You can switch them from one to the
other by selecting the Boot Image and clicking Apply. The system doesn't reboot after it
completes a firmware upgrade.
Select the check boxes beside the card or cards to which you want to upload firmware. You can
simultaneously upload firmware to cards of the same type. You can only upload firmware to cards
that are active.
Click Choose File in the File Path field to select the firmware file you wish to upload. The selected
file's name will display on this screen. After you have specified the file, click Upgrade.
After the firmware upgrade process is complete, use this screen to verify your current firmware
version number.
7.6 Reboot Screen
Click Maintenance > Reboot in the navigation panel to open the following screen. Use this screen
to restart the system without physically turning the power off.
182
Management Switch Card User's Guide