Chapter 12 Statistics Screens
Table 251 IMA Statistics: IMA Line Card: Group Detail: Link Detail (continued)
LABEL
Test Processing
Status
Valid 15 minutes
Interval
Invalid 15 minutes
Interval
TimeElapsed(secs)
Ne State
Fe State
NeFailureStatus
FeFailurStatus
link ID
NeUnusableSecs(s
ecs)
FeUnusableSecs(s
ecs)
Ne Num Failures
Fe Num Failures
Stuffs
TestPattern

12.24.4 Link 15Min

To display the performance of an E1 link on the selected IMA group for the current 15 minutes, click
the slot number in the Statistics > IMA screen, the index number of the IMA group (see
332 on page
496
DESCRIPTION
The field displays the current state of the Test Pattern Procedure.
disabled: The test is stopped.
operating: The test is running and no error has been detected on the link.
linkFail: An error has been detected on this link during the test.
The field displays the number of 15 minute intervals for which valid data was collected.
The value should be 96 unless the IMA group table entry was created within the last 24
hours. In which case the value will be the number of complete 15 minute intervals since
the IMA group table entry was created.
The field displays the number of 15 minute intervals for which no valid data was
available.
The field displays the number of seconds that have elapsed since the beginning of the
current measurement period.
The field displays the current state of the transmission (Tx) or receiving (Rx) link
reported by the IMA line card.
The field displays the current state of the transmission (Tx) or receiving (Rx) link
reported via ICP cells by the remote IMA device.
The field displays the current link failure status of the receiving link reported by the IMA
line card.
The field displays the current link failure status of the receiving link reported via ICP cells
by the remote IMA device.
The field displays the outgoing link identifier (LID) used currently on the link by the IMA
line card (Tx) or by the remote IMA device (Rx).
The field displays the number of unusable seconds in transmission (Tx) or receiving (Rx)
direction detected by the IMA line card.
The field displays the number of unusable seconds in transmission (Tx) or receiving (Rx)
direction detected by the remote IMA device.
The field displays the number of times a transmission (Tx) or receiving (Rx) failure alarm
that have occurred on this link detected by the IMA line card.
The field displays the number of times a transmission (Tx) or receiving (Rx) failure alarm
that have occurred on this link detected by the remote IMA device.
The field displays the number of stuff events inserted in the transmission (Tx) or
receiving (Rx) direction.
The field displays the test pattern received in an ICP cell on the link during the IMA Test
Pattern Procedure. This value may then be compared to the transmitted test pattern.