Table 170 Alarm ADSL Profile (continued)
LABEL
15 Min SESL
[0~900]
15 Min UASL
[0~900]
15 Min Failed
Fast [0~900]
Init Failure Trap
Fast Rate Up
[0~2147483]
(kbps)
Fast Rate Down
[0~2147483]
(kbps)
Interleave Rate
Up [0~2147483]
(kbps)
Interleave Rate
Down
[0~2147483]
(kbps)
Apply
New
Cancel
The bottom part of the screen lists the configured profiles.
Index
Name
Modify
Delete

11.15 Alarm VDSL Profile Screen

Click Profile> Alarm VDSL in the navigation panel to open the following screen. Use this screen to
configure alarm profiles for the VDSL ports. Later you can apply the alarm VDSL profiles to VDSL
ports in the VDSL Port Setup screens.
Alarm VDSL profiles define VDSL port alarm thresholds. The system sends an alarm trap and
generates a syslog entry when the thresholds of the alarm profile are exceeded.
Management Switch Card User's Guide
DESCRIPTION
This field sets the limit for the number of Severely Errored Seconds that are permitted to
occur within 15 minutes.
This field sets the limit for the number of UnAvailable Seconds that are permitted to occur
within 15 minutes.
This field sets the limit for the number of failed fast retrain seconds that are permitted to
occur within 15 minutes.
Select Enable to trigger an alarm for an initialization failure trap.
Specify a rate in kilobits per second (kbps). If a fast mode connection's upstream
transmission rate increases by more than this number, then a trap is sent.
Specify a rate in kilobits per second (kbps). If a fast mode connection's downstream
transmission rate decreases by more than this number, then a trap is sent.
Specify a rate in kilobits per second (kbps). If an interleave mode connection's upstream
transmission rate increases by more than this number, then a trap is sent.
Specify a rate in kilobits per second (kbps). If an interleave mode connection's upstream
transmission rate decreases by more than this number, then a trap is sent.
Click Apply to save the changes in this screen to the system's volatile memory. The
system loses these changes if it is turned off or loses power, so use the Config Save link
on the navigation panel and then the Save button to save your changes to the non-
volatile memory when you are done configuring.
While you are modifying a profile, you can click New to start configuring a fresh profile
without saving your changes.
Click Cancel to start configuring the screen again.
This is the index number of the alarm profile.
This is the name of the alarm profile.
Select a profile's Select radio button and click Modify to edit the profile.
Select a profile's Select radio button and click Delete to remove the profile.
Chapter 11 Profile Screens
365