Chapter 11 Profile Screens
Figure 233 Alarm ADSL Profile
The following table describes the fields in this screen.
Table 170 Alarm ADSL Profile
LABEL
The top part of the screen is for profile configuration.
Name
Threshold
ATU-C
ATU-R
15 Min LOF
[0~900]
15 Min LOS
[0~900]
15 Min LOL
[0~900]
15 Min LPR
[0~900]
15 Min ES
[0~900]
364
DESCRIPTION
Type a name to identify the alarm profile (you cannot change the name of the DEFVAL
profile). You can use up to 31 English keyboard characters; spaces are not allowed.
Specify limits for the individual performance counters. The system sends an alarm trap
and generates a syslog entry when one of these thresholds is exceeded. A value of 0
disables the alarm threshold.
These fields are for traffic coming from the subscriber's device to the system.
These fields are for traffic going from the system to the subscriber's device.
This field sets the limit for the number of Loss Of Frame seconds that are permitted to
occur within 15 minutes.
This field sets the limit for the number of Loss Of Signal seconds that are permitted to
occur within 15 minutes.
This field sets limit for the number of Loss Of Link seconds that are permitted to occur
within 15 minutes.
This field sets the limit for the number of Loss of Power (on the ATUR) seconds that are
permitted to occur within 15 minutes.
This field sets the limit for the number of Errored Seconds that are permitted to occur
within 15 minutes.
Management Switch Card User's Guide