Upbo/Dpbo Electrical Length; Rate Adaption - ZyXEL Communications MSC1000G User Manual

Management switch card
Hide thumbs Also See for MSC1000G:
Table of Contents

Advertisement

Chapter 9 Subscriber Port Setup Screens
ISDN in Europe uses a frequency range of up to 80 kHz, while ISDN in Japan uses a frequency
range of up to 640 kHz. ADSL utilizes the 1.1 MHz band. Both ADSL2 and ADSL 2+ utilize the 2.2
MHz band.
An example is shown next. VDSL Line 1 and ADSL Line 2 are in the same binder. Crosstalk occurs
when the ADSL signal flows from CO (B) and is near to CO (A)'s ONU (Optical Network Unit)
location. Besides, higher Line 1 PSD causes higher interference to the Line 2. CPE (B) receives
signal with higher attenuation. With DPBO enabled on the CO (A), it decreases the PSD level and
reduces the crosstalk impact on other service lines.
Figure 127 DPBO Resolves Downstream Far-End Crosstalk
ADSL
CO (B)

9.2.9 UPBO/DPBO Electrical Length

The distance between a cabinet and the central office is an important parameter of DPBO settings
as mentioned in
distance according to G.997.1 format. Depending on the cable type, the line used and physical line
length, you can calculate the electrical length (in dB). For example, if the distance is 1 kilometer
and you use 24 AWG cable type, the electrical length 20.5 dB is recommended.
The following table displays the calculation from a real length to an electrical length.
Table 90 Real Length to Electrical Length
CABLE TYPE
22 AWG
24 AWG
26 AWG

9.2.10 Rate Adaption

Rate adaption is the ability of a device to adjust from the configured transmission rate to the
attainable transmission rate automatically depending on the line quality. The VDSL transmission
rate then stays at the new rate or adjusts if line quality improves or deteriorates.
The switch determines line quality using the Signal-to-Noise Ratio (SNR). SNR is the ratio of signal
power to noise power. A low SNR indicates poor line quality.
208
VDSL
CO (A)
No-DPBO
DPBO
Section 9.2.8 on page
207. The electrical length is used instead of the real physical
REAL LENGTH TO ELECTRICAL LENGTH
=16.2*(cable length in kilometer)
=20.5*(cable length in kilometer)
=25.8*(cable length in kilometer)
ADSL
Line2 (600m)
CPE (B)
VDSL
Line1 (150m)
CPE (A)
A
B
0
0
0
1
0
1.0039065
Management Switch Card User's Guide
C
0
0
-0.0039065