Updating the Firmware
Errors During Firmware Update
If an error occurs during a download, an error message will appear. The error code consists of the
letter "E" and a number ("E20", for example).
Error Message Table
No.
meaning
20
Cannot map logical address
21
Cannot access memory
Cannot decompress
22
compressed data
Error occurred when ROM
23
update program started
24
SD card access error
No HDD available for stamp
30
data download
Data incorrect for continuous
31
download
Data incorrect after download
32
interrupted
33
Incorrect SD card version
D131/D132/D133
Solution
Make sure the SD card is installed correctly, or
use a different SD card.
HDD connection not correct, or replace hard disk.
The ROM data on the SD card is not correct, or
data is damaged.
Controller program defective. If the second
attempt fails, replace the controller board.
Make sure the SD card is installed correctly, or
use a different SD card.
HDD connection not correct or replace hard disks.
Install the SD card with the remaining data
necessary for the download, then re-start the
procedure.
Do the recovery procedure for the module, then
repeat the installation procedure.
The ROM data on the SD card is not correct, or
data is damaged.