Development Unit

4.7 DEVELOPMENT UNIT

4.7.1 DEVELOPER REPLACEMENT

Preparation

For D133 only, the pressure release tube [A] should be removed before removing the
development unit.
1.
Development unit
2.
Pressure release tube [A]

Removal

1.
Remove the toner hopper [A] (
2.
Rotate the toner hopper very slightly (10° to 20°) as you slide it up to remove it. To avoid toner
spill, hold the hopper level as you remove it
D131/D132/D133
p.4-34
x 2)
4-54
SM