Ricoh D131 Service Manual page 476

Table of Contents

Advertisement

CIS BK level error
The BK level scanned by CIS is abnormal.
The BK level average of R, G or B is/are not from 2 to 62.
SC187
D
0 < Calibrated BK data level < 255(10bit).
Turn off the machine.
Make sure CN210 and CN220 are connected firmly.
Turn on the machine.
CIS white level error
D
The shading data peak detected from the CIS is abnormal.
SC188
CIS defective
Make sure CN210 and CN220 are connected firmly.
-
Replace the CIS.
CIS gray balance adjustment error
The adjustment error occurs during the test after adjusting the gray
balance.
Retry the gray balance adjustment.
SC189
D
If the machine does not recover, do the following steps.
1.
Turn off the machine.
2.
Make sure CN210 and CN220 are connected firmly.
3.
Turn on the machine.
If the machine does not recover, replace the CIS.
Machine serial number error
SC195
D
The number registered for the machine serial number does not match.
Confirm the correct serial number of the machine in the specifications.
-
Important: When SC195 occurs, the serial number must be input.
Contact your technical supervisor.
SM Appendix
2-9
SC100: Scanning