19 Center Lamp Temperature
D131/D132: [150 to 205/200/1 degree C]
D133: [150 to 205/195/1 degree C]
20 End Lamp Temperature
D131/D132: [150 to 205/200/1 degree C]
D133: [150 to 205/195/1 degree C]
21 Center Lamp Actual Time
[0 to 120/60/1 degree C]
22 End Lamp Actual Time
[0 to 120/60/1 degree C]
23 Capacitor Heater Temperature
D131: [170 to 205/200/1 degree C]
D132: [190 to 205/195/1 degree C]
D133: [150 to 205/200/1 degree C]
24 Capacitor Heater Actual Time
[0 to 120/0/1 degree C]
1109
Measure Nip Width
1 Execute
2 Adjust Value
1112
Auto Process Control
Sets the temperature of the hot roller for auto process control to start.
[70 to 150/140/1°C] DFU
SM Appendix
0 or 1
[200 to 400/300/10mm]
3-9
SP1000 Feed
D131/D132/D133