Code
0-15
The other terminal is not
capable of specific functions.
0-16
CFR or FTT not detected after
modem training in confidential
or transfer mode
0-17
Communication was
interrupted by pressing the
Stop key
0-20
Facsimile data not received
within 6 s of retraining
SM
Meaning
Suggested Cause/Action
The other terminal is not capable of accepting
the following functions, or the other terminal's
memory is full.
Confidential RX
Transfer function
SEP/SUB/PWD/SID
Check the line connection.
Replace the FCU.
Try adjusting the TX level and/or cable
equalizer settings.
The other end may have disconnected, or
it may be defective; try calling another
machine.
If the RX signal level is too low, there may
be a line problem.
Cross reference
See error code 0-08.
If the Stop key was not pressed and this error
keeps occurring, replace the operation panel or
the operation panel drive board.
Check the line connection.
Replace the FCU.
Check for line problems.
Try calling another fax machine.
Try adjusting the reconstruction time for
the first line and/or RX cable equalizer
setting.
Cross reference
Reconstruction time - G3 Switch 0A, bit 6
Rx cable equalizer - G3 Switch 07 (PSTN)
63