A3/11"x17" Tray Type 9001 (D482)

2.3.2 INSTALLATION PROCEDURE

Switch the machine off and unplug the machine before starting the following procedure.
1.
Remove the stay [A] ( x 2).
2.
Remove the retainers [B] [C].
3.
Draw out the tandem tray [A] completely to separate the left and right sides of the tray.
4.
Push in the right tandem tray [B].