Code
6-04
G3 ECM - RTC not detected
6-05
G3 ECM - facsimile data
frame not received within 18 s
of CFR, but there was no line
fail
6-06
G3 ECM - coding/decoding
error
6-08
G3 ECM - PIP/PIN received in
reply to PPS.NULL
6-09
G3 ECM - ERR received
6-10
G3 ECM - error frames still
received at the other end after
all communication attempts at
2400 bps
6-21
V.21 flag detected during high
speed modem communication
6-22
The machine resets the
sequence because of an
abnormal handshake in the
V.34 control channel
D619
Meaning
Suggested Cause/Action
Check the line connection.
Check for a bad line or defective remote
terminal.
Replace the FCU.
Check the line connection.
Check for a bad line or defective remote
terminal.
Replace the FCU.
Try adjusting the RX cable equalizer
Cross reference
Rx cable equalizer - G3 Switch 07 (PSTN)
Defective FCU.
The other terminal may be defective.
The other end pressed Stop during
communication.
The other terminal may be defective.
Check for a noisy line.
Adjust the TX levels of the communicating
machines.
See code 6-05.
Check for line noise.
Adjust the TX level (use NCU parameter
01 or the dedicated TX parameter for that
address).
Check the line connection.
Defective remote terminal.
The other terminal may be defective or
incompatible.
Check for line noise.
If the same error occurs frequently, replace
the FCU.
Defective remote terminal.