4.9.7 PRESSURE ROLLER

Use this procedure if you need to remove only the pressure roller.
Remove:
Fusing unit
p.4-70
1.
Turn the fusing unit upside down.
2.
Lower cover [A] (
3.
Pressure roller cleaning unit [B] (
4.
Release the pressure arms [C]
5.
Use screw driver to lower the pressure arms on both ends of the pressure roller.
6.
Pressure roller springs [D]
7.
Pressure roller [E]
The fusing lamps are fragile. Work carefully to avoid breaking them.
During assembly, handle the roller carefully to avoid scratching it on the bracket.
Make sure the tabs and grooves of the lower cover are engaged correctly before
tightening the screw.

Spring Adjustment

Two holes [F] are provided on each pressure arm for the springs.
Normally the springs should be attached to the lower holes.
Attaching the springs to the upper holes exerts less pressure on the hot roller. Attach the
springs to the upper holes only for especially thin paper.