Code
0-21
EOL signal (end-of-line) from
the other end not received
within 5 s of the previous EOL
signal
0-22
The signal from the other end
was interrupted for more than
the acceptable modem carrier
drop time (default: 200 ms)
0-23
Too many errors during
reception
0-29
Data block format failure in
ECM reception
D619
Meaning
Suggested Cause/Action
Check the connections between the FCU
and line.
Check for line noise or other line problems.
Replace the FCU.
The remote machine may be defective or
may have disconnected.
Cross reference
Maximum interval between EOLs and between
ECM frames - G3 Bit Switch 0A, bit 4
Check the line connection.
Replace the FCU.
Defective remote terminal.
Check for line noise or other line problems.
Try adjusting the acceptable modem
carrier drop time.
Cross reference
Acceptable modem carrier drop time - G3
Switch 0A, bits 0 and 1
Check the line connection.
Replace the FCU.
Defective remote terminal
Check for line noise or other line problems.
Try asking the other end to adjust their TX
level.
Try adjusting the RX cable equalizer
setting and/or RX error criteria.
Cross reference
Rx cable equalizer - G3 Switch 07 (PSTN)
Rx error criteria - Communication Switch 02,
bits 0 and 1
Check for line noise or other line problems.
Check the FCU - NCU connectors.
Replace the NCU or FCU.