SC700: Peripherals
SC722-35
D
SC722-36
D
D131/D132/D133
Stack Plate Motor Error 1: Front Motor(D610)
The stack plate HP sensor (front) does not activate within 500 ms
after the motor turns on. The 1st detection failure causes a jam
error, and the 2nd failure causes this SC code.
If the motor is operating
Front stack plate HP sensor harness loose, broken, defective
Front stack plate HP sensor defective
If the motor is not operating:
Motor blocked by an obstruction
Motor harness loose, broken, defective
Motor defective
Booklet finisher main board defective
Stack Plate Motor Error 2: Center Motor (D610)
The stack plate HP sensor (center) does not activate within 500 ms
after the motor turns on. The 1st detection failure causes a jam
error, and the 2nd failure causes this SC code.
If the motor is operating
Center stack plate HP sensor harness loose, broken, defective
Center stack plate HP sensor defective
If the motor is not operating:
Motor blocked by an obstruction
Motor harness loose, broken, defective
Motor defective
Booklet finisher main board defective
2-56
SM Appendix