SC300: Image Development 1
C
SC380-51
-
SC396-01
D
D131/D132/D133
Potential sensor calibration (VL)
During drum potential sensor calibration, when VL is adjusted, the
pattern surface potential VL pattern is not within range 0V to -400V.
(VL is the potential after exposing a white pattern.)
Potential sensor defective
Potential sensor harness disconnected
Potential sensor connector defective or disconnected
IOB defective
OPC connector defective
Charge corona power pack defective
Development power pack defective
Main motor error
The main motor lock signal remains low for 2 seconds while the main
motor is on.
Drive mechanism overloaded
Motor driver board defective
2-22
SM Appendix