Regist: Status
Displays a number that indicates the status of the @Remote service device.
0: Neither the @Remote device nor Embedded RCG Gate is set.
1: The Embedded RCG Gate is being set. Only Box registration is completed.
In this status, @Remote device cannot communicate with this device.
201
2: The Embedded RCG Gate is set. In this status, the @Remote device cannot
communicate with this device.
3: The @Remote device is being set. In this status the Embedded RCG Gate
cannot be set.
4: The @Remote module has not started.
202 Letter Number
Allows entry of the request number needed for the Embedded RCG Gate.
203 Confirm Execute
Executes the confirmation request to the @Remote Gateway.
204 Confirm Result
Displays a number that indicates the result of the confirmation executed with
SP5816-203.
0: Succeeded
1: Confirmation number error
2: Registration in progress
3: Proxy error (proxy enabled)
4: Proxy error (proxy disabled)
5: Proxy error (Illegal user name or password)
6: Communication error
7: Certification update error
8: Other error
9: Confirmation executing
Confirm Place
Displays the result of the notification sent to the device from the Gateway in
205
answer to the confirmation request. Displayed only when the result is
registered at the Gateway.