Ricoh D131 Service Manual page 483

Table of Contents

Advertisement

SC300: Image Development 1
TD sensor output error: Upper Limit
C
TD sensor output voltage (Vt), measured during each copy cycle, is
detected higher than 4V for 10 prints.
SC361-00
-
C
SC362-00
-
D131/D132/D133
TD sensor defective
TD sensor harness disconnected
TD sensor connector disconnected or defective
IOB defective
Toner bottle motor defective
Note: When the TD sensor is defective, the toner supply is
controlled using pixel count and the ID sensor.
TD sensor output error: Lower limit
TD sensor output voltage (Vt), measured during each copy cycle,
is detected 10 times lower than 0.5V.
TD sensor defective
TD sensor harness disconnected
TD sensor connector disconnected or defective
IOB defective
Toner bottle motor defective
Note: When the TD sensor is defective, the toner supply is
controlled using pixel count and the ID sensor.
2-16