26 Using a suitable lifting device, place an
additional 50 lbs / 23 kg of weight onto the
platform.
Result: The alarm should sound and the Valve
Power LED should not light. The platform
overload indicator lights should be flashing at
both the ground and platform controls.
27 Working from outside the platform and standing
next to the platform rotator, locate the orange
wire, which enters into the base of the platform
control box from the load sense switch and
locate the wire terminal at the end of the wire.
Tag and disconnect the connectors.
Refer to Illustration 2.
28 Using a multimeter set to read resistance
(ohms), securely install a lead from the
multimeter to the connector on the orange wire,
and securely connect the other multimeter lead
to a ground point in the control box.
Result: The readout on the multimeter should
indicate zero resistance.
Result: The readout on the multimeter shows
resistance. Remove the machine from service
and contact the Genie Service Department .
29 Using a suitable lifting device, remove all weight
from the platform. Note the result on the
multimeter.
Result: The readout on the multimeter should
indicate infinite resistance.
Result: The readout on the multimeter shows
zero resistance. Remove the machine from
service and contact the Genie Service
Department .
31 Turn off the multimeter and remove the leads
from the machine. Securely connect the wires
disconnected in step 27.
32 Close the platform control box. Install and
securely tighten the fasteners. Do not
overtighten.
Part No. 102521
Section 3 • Scheduled Maintenance Procedures
C-4
Replace the Engine Air Filter
Element - Deutz and Perkins
Models
Genie specifications requires that this procedure
be performed every 500 hours or 6 months,
whichever comes first.
Maintaining the engine air filter in good condition is
essential to good engine performance and service
life. Failure to perform this procedure can lead to
poor engine performance and component damage.
1 Open the evacuator valve located on the air
cleaner cap by squeezing the sides together
with your fingers.
2 Disconnect the latches on the air cleaner cap.
Remove the end cap from the air cleaner
canister.
3 Remove the filter element.
4 Clean the inside of the canister and the gasket
with a damp cloth.
5 Install the new filter element.
6 Install the end cap on the canister and re-
connect the latches.
Note: Be sure the evacuator valve is pointing
down.