the URI in any order. Multiple values given for caller or callee will be concatenated. The following table
shows the parameter list used in the CDR A PI.
Field
Value
format
csv, xml, json
numRecords Number: 0-1000
offset
Number
Comma separated extensions,
caller
ranges of extensions, or regular
expressions.
Example:
caller=5300,5302-5304,_4@
-OR-
callee
caller=5300&caller=5302-5304&
caller=_4@
(Matches extensions 5300, 5302,
5303, 5304, and any extension
containing 4 as the second
digit/character).
Date and/or time of day in any of
startTime
the following formats:
YYYY-MM-DDTHH:MM
YYYY-MM-DDTHH:MM:SS
endTime
YYYY-MM-DDTHH:MM:SS.SSS
(literal 'T' character separator in
Firmware Version 1.0.2.5
Table 108: CDR API URI Parameters
Details
Define the format for output of matching CDR rows.
Default is csv (comma separated values).
Number of records to return. Default is 1000, which is
also the maximum allowed value.
Number of matching records to skip. This will be
combined with numRecords to receive all matches over
multiple responses. Default is 0.
Filters based on src (caller) or dst (callee) value,
matching any extension contained in the parameter input
string.
Patterns containing one or more wildcards ('@' or '_') will
match as a regular expression, and treat '-' as a literal
hyphen rather than a range signifier. The '@' wildcard
matches any number of characters (including zero), while
'_' matches any single character. Otherwise, patterns
containing a single hyphen will be matching a range of
numerical extensions, with non-numerical characters
ignored, while patterns containing multiple hyphens will
be ignored. (The pattern "0-0" will match all
non-numerical and empty strings).
Filters based on the start (call start time) value. Calls
which start within this period (inclusive of boundaries) will
match, regardless of the call answer or end time. A n
empty value for either field will be interpreted as range
with no minimum or maximum respectively.
Strings without a date have a default value of
2000-01-01. Strings without a time of day have a default
value of of 00:00 UTC, while strings with a time of day
UCM6510 IP PBX User Manual