Digital  Trunks; Digital  Hardware  Configuration; Figure  87:  Digital  Hardware  Configuration - Grandstream Networks UCM6510 User Manual

Ip pbx
Hide thumbs Also See for UCM6510:
Table of Contents

Advertisement

 
The  UCM6510  supports  E1/T1/J1  which  are  physical  connection  technology  used  in  digital  network.  T1  is  
the  North   A merican  standard,  J1  is  used  in  Japan,  whereas  E1  is  the  European  standard.    
 
UCM6510   supports   four   signaling   protocols:   PRI,   MFC/R2,   SS7,   E&M   Immediate   and   E&M   Wink.   PRI  
provides  a  varying  number  of  channels  depending  on  the  standards  in  the  country  of  implementation  (E1,  
T1  or  J1);;  MFC/R2  is  a  signaling  protocol  heavily  used  over  E1  trunks;;  SS7  uses  out-­of-­band  signaling,  
which  travels  on  a  separate,  dedicated  channel  rather  than  within  the  same  channel  as  the  telephone  call,  
providing  more  efficiency  and  higher  security  level  when  the  telephone  calls  are  set  up.  E&M  Immediate  
and  E&M  Wink  are  only  valid  when  using  T1  port.  
 
To  set  up  digital  trunk  on  the  UCM6510:  
 
1.   Go  to  web  UI-­>PBX-­>Ports  Config-­>Digital  Hardware  to  configure  port  type  and  channels.  
2.   Go  to  web  UI-­>PBX-­>Basic/Call  Routes-­>Digital  Trunks  to  add  and  edit  digit  trunk.  
3.   Go   to   web   UI-­>PBX-­>Basic/Call   Routes-­>Outbound   Routes   and   Inbound   Routes   to   configure  
outbound  and  inbound  rule  for  the  digital  trunk.  
 
DIGITAL   H ARDWARE   C ONFIGURATION  
 
Go  to  web  GUI-­>PBX-­>Ports  Config-­>Digital  Hardware  page  and  configure  the  following:  
 
Step  1:  Click  on  
•  
Step  2:  Click  on  
•  
channels  can  be  assigned  to  the  default  group;;  for  T1/J1,  23  B  channels  can  be  assigned  to  the  default  
group.  
Step  3:  If  fewer  than  30  B  channels  for  E1  or  23  B  channels  for  T1/J1  are  assigned  in  default  group,  
•  
users   can   click   on  
Firmware  Version  1.0.2.5  
 
DIGITAL   T RUNKS  
Figure  87:  Digital  Hardware  Configuration  
to  edit  digital  ports.  Please  see  configuration  parameters  in  the  tables  below.  
to  edit  group.  This  assigns  channels  to  be  used  for  the  digital  port.  For  E1,  30  B  
  to   add   more   groups.   This   is   not   necessary   in   most   cases   and   only   default  
UCM6510  IP  PBX  User  Manual  
 
 
3  
1  
2  
 
 
Page  148  of  317