Model 830 Fc 9074, Model 840 Fc 9079/8079 (With Dual Line Cords) - Ac Module (A01, A02); Models 830/Sb2 With Fc 9074 - Amd (Bp1 And Bp2) - IBM i 830 Repair Manual

Table of Contents

Advertisement

Remove and Replace Procedures
3. Remove the power cords from the AC Input/Charger.
4. Remove the top and bottom screws that hold the AC Input/Charger to the
5. Pull the AC Input/Charger out of the frame.
6. Install the AC Input/Charger by reversing the removal procedure. After
This ends the procedure.
Model 830 FC 9074, Model 840 FC 9079/8079 (With Dual Line Cords) –
AC Module (A01, A02)
1. Do Not Power Down the tower if it is powered on. (This can be done
2. Open the rear cover. See "Models 830/SB2 with FC 9074 – Covers" on page 663
3. See the "Locations and Addresses" on page 705 for the tower that you are
4. Trace the AC input line cord that connects to AC module that needs replacing
5. Disconnect the power supply jumper cords from the AC module that you are
6. Remove the top and bottom screws that hold the AC module to the frame.
7. Remove the AC module unit.
8. Install the AC module by reversing the removal procedure. After exchanging an
This ends the procedure.
Models 830/SB2 with FC 9074 – AMD (BP1 and BP2)
1. Do not power off the system.
2. Remove the front cover, see "Models 830/SB2 with FC 9074 – Covers" on
Refer to "Assembly 2: Models 830 and SB2 with FC 9074 – Final Assembly, Front"
3. Remove the upper EMC access plate.
4. Remove the AMD mounting screws (x2) from the upper left and upper right
5. Remove the AMD by pulling upwards on the pull rings and lifting the AMD
6. Install the AMD by reversing the removal procedure. After exchanging an item,
This ends the procedure.
654
iSeries Model 830, 840, SB2, and SB3 Problem Analysis, Repair and Parts V5R1
frame.
exchanging an item, go to "Verifying the Repair" on page 920.
concurrently.)
or "Models 840/SB3 – Covers" on page 690, depending on the model that you
are working on.
working on.
and disconnect that AC line cord.
Attention: Do not disconnect the other system AC line cord when powered
on.
working on.
Attention: Do not disconnect the other system AC module power supply
jumper cords.
item, go to "Verifying the Repair" on page 920.
page 663.
on page 806 and perform the following steps.
hand corners of the AMD that you are replacing.
out of the system.
go to "Verifying the Repair" on page 920.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

I sb3I 840I sb2

Table of Contents