Table of Contents

Advertisement

Symbolic FRUs
14. Is the SRC 1xxx B201 or B202?
15. Go to "Starting Point for All Problems" on page 4.

PWRSPLY

A power supply may be the failing item.
Note: The C in the SRC (1xxC xxxx) indicates the problem is on the processor
If the LED in a power supply is not on or is blinking, it may be the failing item.
The LED not on may be the only indication of a failure. Exchange the power
supply to correct this problem.
Find the unit reference code in the following list to determine the failing power
supply and the part number. Then see "Chapter 5. Locations, Addresses, and Part
Listings" on page 705 to determine the location, and the correct remove and replace
procedure for the failing item.
Perform the following to determine the part number for the failing power supply:
576
iSeries Model 830, 840, SB2, and SB3 Problem Analysis, Repair and Parts V5R1
v Base I/O tower (FC 5077) – part 21H4829
v Symbolic FRU BATCHGR
This ends the procedure.
No
Yes
If the system can be powered on with this SRC, perform symbolic
FRU BATCHGR, and then continue.
The battery unit is reporting an over-current.
The following list shows the possible failing items:
v Regulator – part 23L3603 OR 21H7763
v Battery charger – part 21H7060
v Symbolic FRU BATCHGR
This ends the procedure.
tower side of the Model 840 system type.
1. Is the SRC 1xxx-11xx?
No
Yes
For 1xxx-11xx SRCs use this table:
Unit Reference Code
1100
1101
1102
1103
1104
1105
Notes:
a. If the new power supply doesn't fix the problem, reinstall the original
power supply.
Power Supply
P01
P02
P03
P04
P05
P06
Part Number
21H7719
21H7719
21H7719
21H7719
21H7719
21H7719

Hide quick links: