IBM i 830 Repair Manual page 508

Table of Contents

Advertisement

Failing Items
Description/Action If only a type number is listed, go to the "Type, Model, and Part
Failing Item Code
Number list" on page 885 to determine the part number.
FI01110
FI01110 indicates that the diskette unit is the failing item.
Use the diskette device type to determine the part.
FI01112
FI01112 indicates that the active IOP is the failing item.
Perform the following:
1. Find the IOP address (see "SRC Address Formats" on page 936).
2. To determine the location of the I/O processor card, see "Locations and Addresses" on
3. Use the IOP type to determine the part.
FI01117
FI01117 indicates that any IOA, card, cable, or device attached to the IOP may be the failing
item.
1. Find the IOP address (see "SRC Address Formats" on page 936).
2. To determine the location of the I/O processor card, see "Locations and Addresses" on
3. Identify the IOAs, cards, cables, and devices attached to the IOP found in the preceding
4. Exchange the IOAs, cards, cables, and devices attached to the IOP one at a time until
FI01119
See the symbolic FRU "BACKPLN" on page 504.
FI01121
This failing item is in a migrated tower. See the Migrated Expansion Tower Problem Analysis,
Repair and Parts failing item table for this failing item.
FI01130
This failing item is in a migrated tower. See the Migrated Expansion Tower Problem Analysis,
Repair and Parts failing item table for this failing item.
FI01131
This failing item is in a migrated tower. See the Migrated Expansion Tower Problem Analysis,
Repair and Parts failing item table for this failing item.
FI01132
This failing item is in a migrated tower. See the Migrated Expansion Tower Problem Analysis,
Repair and Parts failing item table for this failing item.
FI01140
FI01140 indicates that the I/O (SCSI) bus cable is the failing item.
Perform the following:
1. Are there external devices attached?
2. Find the IOP address (see "SRC Address Formats" on page 936).
3. To determine the location of the I/O processor card, see "Locations and Addresses" on
4. Exchange the failing item associated with the IOP address.
494
iSeries Model 830, 840, SB2, and SB3 Problem Analysis, Repair and Parts V5R1
page 705.
page 705.
steps.
you have corrected the problem.
No
Yes
For SCSI attached external devices, see "EXTSCSI" on page 535.
For Fibre Channel attached external devices, see "FCCABLE" on page 537.
page 705.
Note:
Any of the SCSI cables or backplanes between the IOA and the device could be the
failing item. See "Power and Signal Cables" on page 779.