Symbolic FRUs
Figure 12. Control PANEL DIAGRAM FOR FUNCTION A8:
15. Perform the following to set frame Configuration ID:
542
iSeries Model 830, 840, SB2, and SB3 Problem Analysis, Repair and Parts V5R1
d. The Configuration ID should now be displayed for the non-system unit.
For a system unit, use the arrow keys to increment/decrement the
sub-function field to display the configuration ID for the CEC.
The Configuration ID displayed is defined as follows:
80
81
82
83
84
90
Is the correct configuration ID displayed for the tower selected?
No
Yes
Go to 17 on page 543 of this procedure.
Note: The System or Frame that the ID is being set on MUST be powered
down with AC applied.
a. Select Function 07 on the system control panel. Press Enter. (07** will be
displayed)
b. Use the arrow keys to increment/decrement to sub-function A9. (07A9 will
be displayed). Press Enter. (07A9 00 will be displayed)
c. Use the arrow keys to increment / decrement to the frame address of the
box you want to set the Configuration ID (usually 02, 03, etc. for the
towers, 01 for system unit frames). (07nn will be displayed where nn is the
frame address) Press Enter. (07nn 00 will be displayed)
Note: The display on the addressed frame should now be blinking on and
off (Non-system unit only).
d. Select the correct Configuration ID from the following table:
80
81
82
83
FC 5065/5066
FC 5074/5079, FC 8079 (002)
FC 9079 (On Model 840), FC 8079 (001)
FC 9074 (On Model 830)
FC 5078/0578
FC 5075
FC 5065/5066
FC 5074/5079, FC 8079 (002)
FC 9079 (On Model 840), FC 8079 (001)
FC 9074 (On Model 830)