Operations Console-Pip3 - IBM i 830 Repair Manual

Table of Contents

Advertisement

Operations Console-PIP3

This problem isolation procedure will isolate an Operations Console bringup
failure when the SRC on the panel is A6xx5008 or B6xx5008 only.
This PIP works with cable-connected and Lan configurations only. It is not valid
for dial connected configurations.
Note: Determine if the system has logical partitions. Go to "Determining if the
System Has Logical Partitions" on page 943 before continuing with this
procedure. If the system has logical partitions, perform this procedure from
the logical partition that reported the problem.
Perform the following:
1. Is the SRC on the panel A6xx5008 or B6xx5008?
Yes
No
This ends the procedure.
2. Are you connecting Operations Console using the ASYNC adapter?
Yes
No
You are connecting using a LAN adapter. Go to step 9 of this
procedure.
3. Are words 17, 18, and 19 all equal to 00000000?
No
Yes
Report the problem to your next level of support.
This ends the procedure.
4. Is word 17 equal to 00000001?
No
Yes
The ASYNC adapter was not detected. Ensure that the ASYNC
adapter card is installed, or replace the IOA and try again.
This ends the procedure.
5. Is word 17 equal to 00000002?
No
Yes
On the ASYNC adapter card that was found, no cable was detected.
Word 18 contains the card position. Locate the ASYNC adapter card in
this card position, and ensure that the external cable is attached.
Install or replace the external cable.
This ends the procedure.
6. Is word 17 equal to 00000003?
No
Yes
The cable that was detected does not have the correct cable ID. Word
18 contains the card position. Word 19 contains the cable ID. Locate
the ASYNC adapter card in this card position, and verify that the
correct cable is attached, or replace the cable.
This ends the procedure.
7. Is word 17 equal to 00000004?
No
Yes
Chapter 3. Problem Isolation Procedures (PIPs), Failing Items, and Symbolic FRU Isolation
Operations Console PIPs
385

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

I sb3I 840I sb2