IBM i 830 Repair Manual page 178

Table of Contents

Advertisement

7208
Reference Code
Description/Action Perform all actions before exchanging Failing Items
3002
I/O processor addressed the tape unit; no response
The tape unit did not respond to a command sent by the IOP.
1. Ensure that the tape unit is powered on. If the tape unit does not
become powered on, refer to the "Maintenance Analysis Procedures" in
the 7208 Model 2 8 mm Tape Drive Service Guide, SA23-2640, to analyze
the problem.
2. Switch off power to the tape unit.
3. Reseat the signal cable to the tape unit.
4. Reseat the signal cable to the IOP.
5. Switch on power to the tape unit.
3005
Blank tape or BOT encountered
The tape unit has found blank tape or BOT.
When using a new data cartridge, the tape must first be initialized.
This error can also occur when reading a tape if the tape was removed
from the tape unit before writing was complete.
Also see the procedure for reference code FFFF.
3010
Illegal or unsupported tape unit response
1. Look at the In-use lights. If the green light is off and the yellow light is
on, the tape unit is indicating an error condition.
2. Switch off power to the tape unit.
3. Switch on power to the tape unit.
4. Clean the recording head in the tape unit. Use the IBM Cleaning
Cartridge Kit (part 21F8593).
5. Use a new data cartridge if saving data.
Also see the procedure for reference code FFFF.
3100
IOP to tape unit interface error
1. Ensure that the tape unit is powered on. If the tape unit does not
become powered on, refer to the "Maintenance Analysis Procedures" in
the 7208 Model 2 8 mm Tape Drive Service Guide, SA23-2640, to analyze
the problem.
2. Switch off power to the tape unit.
3. Reseat the signal cable to the tape unit.
4. Reseat the signal cable to the IOP.
5. Switch on power to the tape unit.
3110
Tape unit command timeout
The tape unit did not complete a command sent by the IOP in the time
allowed.
1. Ensure that the tape unit is powered on. If the tape unit does not
become powered on, refer to the "Maintenance Analysis Procedures" in
the 7208 Model 2 8 mm Tape Drive Service Guide, SA23-2640, to analyze
the problem.
2. Switch off power to the tape unit.
3. Reseat the signal cable to the tape unit.
4. Reseat the signal cable to the IOP.
5. Switch on power to the tape unit.
164
iSeries Model 830, 840, SB2, and SB3 Problem Analysis, Repair and Parts V5R1
Failing Item
91F0914
81F9128
FI00830
FI00141
91F0721
53F3861
42F7300
MLVTMED
91F0914
AJEDA00
91F0914
AJEDA00
91F0914
FI00141
FI00830
91F0721
42F7300
53F3861
81F9128
AJEDA00
91F0914
FI00141
FI00830
91F0721
42F7300
53F3861
81F9128
AJEDA00

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

I sb3I 840I sb2

Table of Contents