Bus, High-Speed Link (HSL) PIPs
14. Select "cancel" and then go to step 19 of this procedure.
15. Locate the I/O processor in HSM by performing the following for each IOP:
16. Select "cancel".
17. Select "cancel" again and go to step 19 of this procedure.
18. Page forward until you find the multi-adapter bridge and IOP where the
19. Select the "Resources associated with IOP" option for the IOP that you are
20. Move the cursor to the first IOA that is assigned to the IOP.
21. Select the "Associated packaging resource(s)" option for the IOA where the cursor
22. Select option "Concurrent maintenance" for the IOA.
23. Select function "Power off domain".
24. Perform "BUS PIP IOP-01, IOP Reset" on page 308, then return here and
25. Did the IOP reset and IPL successfully?
26. Check for the same failure that sent you to this procedure. Check the system
27. Did the same SRC occur after the IOP was reset and IPL'd?
310
iSeries Model 830, 840, SB2, and SB3 Problem Analysis, Repair and Parts V5R1
Note: The card information on the HSM display is in decimal format. You
must convert the decimal card information in to hexadecimal format
to match the DSA format.
Decimal Format
16
17
18
19
20
21
22
23
c. Repeat this step until you find the IOP with the same DSA.
a. Select the "Associated packaging resource(s)" option.
b. Select the "Display detail" option.
c. Repeat this step until you find the IOP with the same location.
problem exists. Verify that the multi-adapter bridge and IOP are correct by
matching the resource name(s) on the screen with the resource name(s) in the
"Service Action Log" (SAL) for the problem that you are working on.
working on (if the I/O adapters are not already displayed).
is located.
Did the domain power off successfully?
Yes
No
This procedure will not be able to identify a failing I/O adapter.
Return to the procedure that sent you here.
continue with step 25 of this procedure.
Yes
No
This procedure will not be able to identify a failing I/O adapter.
Return to the procedure that sent you here.
control panel, the SAL for the partition that reported the problem, or the Work
with partition status screen for the partition that reported the problem. In the
SAL the count will increase if the SRC occurred again.
Yes
No
Go to step 31 on page 311 in this procedure.