Table 17.
System Model
830 and SB2
840 and SB3
This ends the procedure.

BUS1

The failing item is any card, cable or card enclosure connected to bus 1 that might
cause an interface failure between the service processor and the system unit
processor.
The System Unit or the Base I/O Tower has failed and the diagnostic software was
not able to isolate the failure to a single FRU.
Check the last IPL status code in SRC data word 3 in the second half of control
panel function 12.
12
xxxxxxxxxxxxSSSS
xxxxxxxxxxxxxxxx
If this value is 2000 through 2009 then use the IPLINTF symbolic FRU instead of
following this procedure. If this value is 200A through 2018 then follow this
procedure.
1. Attempt a SLOW OVERRIDE IPL to run full processor hardware diagnostics.
Power off the system from the control panel. Change the IPL mode to manual,
and the IPL speed to SLOW OVERRIDE (S) using control panel function 2.
Power on the system.
Does the same SRC occur ?
Yes
No
Follow the service actions for the new SRC.
2. Power off the system from the control panel. Check the cables and connections
between the System Unit and the Base I/O Tower. Reseat cables where
possible.
Power on the system.
Does the same SRC occur ?
Yes
No
Follow the service actions for the new SRC.
Chapter 3. Problem Isolation Procedures (PIPs), Failing Items, and Symbolic FRU Isolation
Name of FRU to
FRU Position
Exchange
Tower Card
CB1
Tower Card
CB1
SSSS = IPL status code
Symbolic FRUs
Link to Location
Link to Failing
Diagram
Component
Service
Information.
(CCIN, PN,
Removal and
Installation
Procedure)
"Locations —
Table 41 on
Models 830, SB2
page 710.
System Unit
with FC 9074
Base I/O Tower"
on page 709.
Figure 36 on
Table 43 on
page 724.
page 725.
507