Disk Unit Failing Items - IBM i 830 Repair Manual

Table of Contents

Advertisement

Reference Code
Description/Action Perform all actions before exchanging Failing Items
FFF4
Disk device problem
FFF5
Disk sector read error
A disk unit service action is recommended only if the Service Action Log
contains an entry for this reference code. For more information about the
Service Action Log, see "Hardware Service Manager" in the iSeries Service
Functions.
FFF6
Disk device detected recoverable error
A disk unit service action is recommended only if the Service Action Log
contains an entry for this reference code. For more information about the
Service Action Log, see "Hardware Service Manager" in the iSeries Service
Functions.
FFF7
Temporary disk data error
No action required. This reference code is logged for information only.
FFF8 to FFF9
Temporary disk data error
A disk unit service action is recommended only if the Service Action Log
contains an entry for this reference code. For more information about the
Service Action Log, see "Hardware Service Manager" in the iSeries Service
Functions.
FFFA
Temporary disk bus error
A disk unit service action is recommended only if the Service Action Log
contains an entry for this reference code. For more information about the
Service Action Log, see "Hardware Service Manager" in the iSeries Service
Functions.
FFFE
Temporary disk bus error
A disk unit service action is recommended only if the Service Action Log
contains an entry for this reference code. For more information about the
Service Action Log, see "Hardware Service Manager" in the iSeries Service
Functions.

Disk Unit Failing Items

Notes:
1. To determine the failing items, go to "Failing Items" on page 479.
2. To determine the associated part numbers, go to "Type, Model, and Part
3. To determine the parts associated with symbolic FRUs, such as "ANYBUS", or
Failing Item
Description
BACKPLN
Card enclosure or backplane
CMPRES1
Compressed device and compression IOA are
not compatible
DEVTERM
Device terminator
DISKDRV
Disk drive and logic card
Number list" on page 885.
"DEVTERM", go to "Symbolic FRUs" on page 495.
432x, 660x, 671x, 673x
Document Description
Problem Analysis; Symbolic FRU Isolation
Problem Analysis; Symbolic FRU Isolation
Problem Analysis; Symbolic FRU Isolation
Problem Analysis; Symbolic FRU Isolation
Chapter 2. Unit Reference Codes
Failing Item
DISKDRV
FI01112
DISKDRV
DISKDRV
DISKDRV
DISKDRV
DISKDRV
FI01112
BACKPLN
FI01141
FI01140
DEVTERM
DISKDRV
FI01112
FI01106
DISKTRY
FI01141
FI01140
BACKPLN
DEVTERM
153

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

I sb3I 840I sb2