IBM i 830 Repair Manual page 456

Table of Contents

Advertisement

Service Processor PIPs
442
iSeries Model 830, 840, SB2, and SB3 Problem Analysis, Repair and Parts V5R1
Value for EEEE and Description:
210E: Load source internal error.
2111: Load source device became
non-operational.
2121: Less data was transferred than was
requested, during an IPL command.
2124: Load source IOP failed.
212A: Load source device not responding.
212D: Bad error log data format
214x: Load source IOP time out
Recommended Service Action:
If the SRC data word 16 in control panel
function 13 is 00001070, then:
The service processor encountered an error
while communicating with the load source
IOP. The DSA of the load source IOP is in
SRC data word 17, in control panel function
13. Replace the load source IOP or the
service processor hardware (SVCPROC).
If the SRC data word 16 in control panel
function 13 is 00400000, then:
The load source IOP encountered an error
while communicating with the load source
device. The device unit address is in SRC
data word 18, in control panel function 13.
Replace the first storage IOA, or the load
source device unit or isolate a problem on
that device interface.
If the SRC data word 16 in control panel
function 13 is BFD00009, then:
The service processor encountered an error
on a PCI adaptor. The DSA of the load
source IOP is in SRC data word 17, in
control panel function 13. Replace the load
source IOP or the first storage IOA.
The load source IOA encountered an error
while communicating with the load source
device. The device unit address is in SRC
data word 18, in control panel function 13.
Replace the load source device unit or
isolate a problem on that device interface.
The load source IOP reported that the data
available for transfer was less than
requested. Replace the service processor
hardware (SVCPROC) or the load source
IOP.
The load source IOP reported a fatal error,
but did not provide any other information.
Replace the load source IOP.
The load source device did not respond to
the first storage IOA when queried. The load
source device may not be powered on or
connected correctly. Check the cabling for
the load source device, or replace the load
source device.
The load source IOP encountered and error
and built an error log entry. The service
processor retrieved the error log data but it
was in an incorrect format. Replace the load
source IOP.
The load source IOP did not respond in time
to a command from the service processor.
Replace the load source IOP.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

I sb3I 840I sb2

Table of Contents