Qsysopr; Refer - IBM i 830 Repair Manual

Table of Contents

Advertisement

This ends the procedure.
12. Is the SRC 1xxx 2330 or 2331?
No
Yes
The failing item is power supply 1 on a base expansion unit:
v Model FC 5033, 5034 – part 21H9364
v Model FC 5035 – part 44H7779
Note: FC 5035 may contain up to 4 power supplies. The reference
This ends the procedure.
13. Is the SRC 1xxx 2213?
No
Yes
See next failing item.
This ends the procedure.
14. Is the SRC 1xxx 2210?
No
Yes
The failing item is Power Supply 1 on the base expansion unit, or
Power Supply 2 on the internal expansion unit of a Model FC 5035
expansion:
v Model FC 5033, 5034 – part 21H9364 (power supply 1)
v Model FC 5035 – part 44H7779 (power supply2)
Note: See the Locations and Addresses section in Migrated Expansion
This ends the procedure.
15. Go to "Starting Point for All Problems" on page 4.
This ends the procedure.

QSYSOPR

For more information, look in the System Operator message queue for a message
with the same date/time. Perform any actions defined in the message.
This ends the procedure.

REFER

Consult the appropriate 3995 Optical Library Dataserver Maintenance Information
Manual to assist in analyzing the URC.
This ends the procedure.
Chapter 3. Problem Isolation Procedures (PIPs), Failing Items, and Symbolic FRU Isolation
code that sent you here refers to the power supply on the base
expansion unit (see the Locations and Addresses section in
Migrated Expansion Tower Problem Analysis, Repair and Parts.)
Tower Problem Analysis, Repair and Parts.
Symbolic FRUs
581

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

I sb3I 840I sb2

Table of Contents