Description/Action If only a type number is listed, go to the "Type, Model, and Part
Failing Item Code
Number list" on page 885 to determine the part number.
FI00301
FI00301 indicates that the magnetic storage I/O processor (MSIOP) or the combined
function I/O processor (CFIOP) is the failing item.
Use the IOP type to determine the part.
FI00302
FI00302 indicates that the Licensed Internal Code for the magnetic storage I/O processor
(MSIOP) or the combined function I/O processor (CFIOP) is the failing item.
Ask your next level of support for assistance.
FI00310
FI00310 indicates that an I/O processor card or an I/O adapter card is the failing item.
Perform Bus PIP 1 in Migrated Expansion Tower Problem Analysis, Repair and Parts to
determine the failing item.
FI00315
FI00315 indicates that the battery power unit install time life has been exceeded.
FI00316
FI00316 indicates that no I/O processors were found on the bus.
Verify the configuration information for the system. If a bus is configured to be empty,
there is no problem.
FI00317
FI00317 indicates that the I/O processor cards at consecutive direct select addresses appear
to be failing.
The I/O processor cards or a damaged backplane could cause this problem.
FI00318
FI00318 indicates that an I/O adapter card attached to an I/O processor card on the failing
bus is the failing item.
FI00319
FI00319 indicates that the Licensed Internal Code on an I/O processor is the failing item.
Install a PTF to correct the problem.
Ask your next level of support for assistance.
FI00320
FI00320 indicates that the display station used as the console is the failing item.
FI00350
FI00350 indicates that the alternate IPL device is the failing item.
See the service information for the specific device type and model installed on the system
to determine the part.
FI00360
FI00360 indicates that the IPL disk device is the failing item.
FI00380
On the bus with the system console or the failing logical partition's console the failing item
is the first workstation IOP card or the workstation IOA card. The bus with the system
console is bus 0001. For systems with multiple logical partitions the Primary partition's
console is on bus 0001 and the consoles for other logical partitions are determined by the
LPAR configuration.
FI00500
See "FI01140" on page 494
FI00580
FI00580 indicates that any storage device may be the failing item.
The address of the failing storage device cannot be determined.
FI00581
FI00581 indicates that a storage device at the address identified by the problem isolation
procedures for the reference code is the failing item.
Use the service information of the I/O device to continue analyzing the problem.
FI00584
FI00584 indicates that any storage device may be the failing item.
The address of the failing storage device cannot be determined.
FI00601
FI00601 indicates that the display station is the failing item.
If a link protocol converter is used to connect the console to the system, the protocol
converter is the failing item.
Chapter 3. Problem Isolation Procedures (PIPs), Failing Items, and Symbolic FRU Isolation
Failing Items