Failing Items
Description/Action If only a type number is listed, go to the "Type, Model, and Part
Failing Item Code
Number list" on page 885 to determine the part number.
FI00882
FI00882 indicates that the addressed unit is the failing item.
Determine the address and type of the failing unit (see "System Reference Code (SRC)
Record" in the iSeries Service Functions information).
If one of the following device types is the failing item, see the service information for the
device model installed on the system: v 2440 v 3490 v 3570 v 3590 v 3995 v 63A0 v 7208 v 9347v
9348 v 9427.
If the tape unit being used is in the FC 5032 Removable Storage Unit, the failing item is the
636x Tape Unit.
See "Removable Storage Unit (FC 5032)" in the SY44-4934-00, FC 504x Problem Analysis
and Repair and Parts information.
Note: The FC 5032 DSE module connects tape units as follows:
v Tape units in the top 5032 locations (positions 1 and 2) use the top external cable
v Tape units in the bottom 5032 locations (positions 3 and 4) use the bottom external cable
A tape unit to the left or right of the tape unit being used (in position 1 or 2 or in position
3 or 4) may be causing the failure.
A tape unit above or below the tape unit being used is not a probable cause of the failure
because it is attached to a different internal FC 5032 DSE I/O bus and, as described above,
uses the other external signal cable.
FI00883
FI00883 indicates that a unit attached to the same IOP, other than the addressed unit
identified by FI00882, is the failing item.
FI00884
FI00884 indicates that any unit attached to the IOP may be the failing item.
See FI00882 for the list of possible units.
FI01040
FI01040 indicates that you have an OptiConnect/400 system, and the error is on an iSeries
400 system that is connected to it.
FI01101
FI01101 indicates that the addressed IOA card on the I/O processor is the failing item.
Perform the following:
1. Determine the address of the IOA card (see "SRC Address Formats" on page 936).
2. Determine the location of the IOA card (see "Locations and Addresses" on page 705).
3. Exchange the failing device. Use the device type to determine the part.
FI01103
FI01103 and FI01104 indicate that an attached IOA card is the failing item.
Perform "BUS-PIP5" on page 285 to isolate the failing IOA.
FI01104
See FI01103.
492
iSeries Model 830, 840, SB2, and SB3 Problem Analysis, Repair and Parts V5R1
connector.
connector.