Reference Code
Description/Action Perform all actions before exchanging Failing Items
0183
WS IOP detected wrong display size value
Perform "TWSC-PIP1" on page 465.
0184
WS IOP detected wrong keyboard identification
Verify that the correct keyboard is attached correctly to the workstation.
If the correct keyboard is attached correctly to the workstation, perform
"TWSC-PIP1" on page 465.
0189
Wrong magnetic stripe reader or light pen status
Perform "TWSC-PIP1" on page 465.
0190
WS IOP detected no status change from device
Is the problem intermittent?
No
Perform "TWSC-PIP1" on page 465.
0191
WS IOP detected busy time-out from device
Perform "TWSC-PIP1" on page 465.
0200
Device no response time-out; temporary error
0201
WS IOP detected error when transmitting data
Is the problem intermittent?
No
Perform "TWSC-PIP1" on page 465.
0203
WS IOP detected parity error from device
Is the problem intermittent?
No
Perform "TWSC-PIP1" on page 465.
Yes
Perform the following procedures:
1. "INT-PIP5 External Noise on Twinaxial Cables" on page 333
2. "INT-PIP14 Station Protectors" on page 339
Yes
Perform the following procedures:
1. "INT-PIP5 External Noise on Twinaxial Cables" on page 333
2. "INT-PIP14 Station Protectors" on page 339
Yes
Perform the following procedures:
1. "INT-PIP5 External Noise on Twinaxial Cables" on page 333
2. "INT-PIP14 Station Protectors" on page 339
Failing Item
FI00601
FI00601
FI00601
FI00605
FI00607
FI00610
FI00601
FI00610
GAU7777
FI00601
FI00610
FI00604
FI00602
FI00610
FI00602
FI00604
GAU7777
GAU8888
FI00610
FI00615
FI00602
FI00604
GAU7777
FI00610
Chapter 2. Unit Reference Codes