IBM i 830 Repair Manual page 510

Table of Contents

Advertisement

Symbolic FRUs
2. On the system unit, the 00AC reference code can be caused by an SPCN
3. Is the failing AC module on a system unit?
4. Is the SRC 00AC, CB05, or CB06 on a system with 1 AC module?
5. Is the SRC 00AC, 01AC, 02AC, 7410, 7411, 7412, 7413, 7414, 7415, or 7416?
496
iSeries Model 830, 840, SB2, and SB3 Problem Analysis, Repair and Parts V5R1
Yes
No
Go to step 3 of this procedure.
frame-to-frame cable problem. This usually occurs between the system unit and
the FC 9079 Base I/O Tower. See the symbolic FRU "CBLALL" on page 512 for
a parts list. Return here and continue with the next step of this procedure if the
problem is not resolved.
Yes
No
Go to step 8 on page 497 of this procedure.
No
Yes
For Model 840/SB3 processor tower:
v USA - part 21H7000
v World Trade 1PH - part 21H7261
v World Trade 2PH - part 21H7264
v AC line cord
If SRC prevails – see Symbolic FRU "BKSPCN" on page 506
No
Yes
Notes:
a. For SRC 00AC, 01AC or 02AC, "Power PIP11" on page 396 must be
performed before replacing parts.
b. Check the error log when SRC 7412 and 7413 are both logged at the
same time.
01AC, 7410, 7412, 7414 exchange:
v AC module 1 USA – part 21H7000
v World Trade 1PH – part 21H7261
If SRC prevails, exchange concurrent maintenance adapter card – part
04N6092
02AC, 7411, 7413, 7415 exchange:
v AC module 2 USA – part 21H7000
v World Trade 1PH – part 21H7261
If SRC prevails, exchange concurrent maintenance adapter card – part
04N6092
00AC, exchange:
v AC module 1 and 2 USA – part 21H7000
v World Trade 1PH – part 21H7261
If SRC prevails, exchange concurrent maintenance adapter card – part
04N6092
7416, exchange:

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

I sb3I 840I sb2