21. The IPL or Install the System display is on the console.
Check for the SRC in the service action log (see "Using the Service Action
Log" on page 9).
Did you find the same SRC that sent you to this procedure?
Yes
No
Go to "BUS PIP VERIFY - RA" on page 323.
This ends the procedure.
22. Perform the following:
a. Power off the system.
b. Remove the IOP card you just exchanged and install the original card.
c. Go to "BUS-PIP1" on page 285.
This ends the procedure.
23. Ask your next level of support for assistance and report a Licensed Internal
Code problem.
You may be asked to verify that all PTFs have been applied.
If you are asked to perform the following, see the iSeries Service Functions
information:
v Copy the main storage dump from disk to tape or diskette.
v Print the product activity log.
v Copy the IOP storage dump to removable media.
This ends the procedure.

LIC-PIP8

Note: Determine if the system has logical partitions. Go to "Determining if the
System Has Logical Partitions" on page 943, before continuing with this
procedure.
Note: If the system has logical partitions, perform this procedure from the logical
partition that reported the problem.
Licensed Internal Code detected an operating system program problem.
Read the "Overview" on page 341 before continuing with this procedure.
1. Select manual mode and perform an IPL to DST (see "Dedicated Service Tools
(DST)" in the iSeries Service Functions information).
Does the same SRC occur?
No
Yes
Go to step 6 of this procedure.
2. Does the same URC appear on the console?
No
Yes
Go to step 5 of this procedure.
3. Does a different SRC occur, or does a different URC appear on the console?
No
Yes
Use the new SRC or reference code to correct the problem (see
Chapter 3. Problem Isolation Procedures (PIPs), Failing Items, and Symbolic FRU Isolation
LIC PIPs
349