Uc235; Uc236 - IBM i 830 Repair Manual

Table of Contents

Advertisement

Table 40. (continued)
System Model,
Tower,
Expansion
Unit, or
Machine Type
FC 5078/0578
PCI expansion
unit
FC 5079 (1.8m
expansion
tower)
Models 830
and SB2 base
I/O tower (FC
9074)
Models 840
and SB3 base
I/O tower (FC
9079)
This ends the procedure.

UC235

The problem may be that the card (a resource) was removed from the card
enclosure without updating the system configuration records.
Note: If the system has OptiConnect/400, verify that the remote system was
powered on at the time of the failure.
If a resource was removed from the system without updating the system
configuration records, then use Hardware System Manager, Logical Hardware
Resources, System Bus Resources, Non-reporting Resources, and use the remove
option to remove the resource from the system configuration records.
This ends the procedure.

UC236

The problem may be that the card (a resource) is not correctly plugged into the
card enclosure. Use the location information associated with this filing item in the
Service Action Log entry and verify that the card is installed properly.
This ends the procedure.
Chapter 3. Problem Isolation Procedures (PIPs), Failing Items, and Symbolic FRU Isolation
Name of FRU
FRU Position
to Exchange
Tower Card
CB1
Tower Card
CB1
Tower Card
CB1
Tower Card
CB1
Symbolic FRUs
Link to
Link to Failing
Location
Component Service
Diagram
Information. (CCIN,
PN, Removal and
Installation Procedure)
"Locations —
Table 46 on page 744.
FC 5078, 0578
PCI Expansion
Unit" on
page 743.
"Locations —
Table 44 on page 737.
FC 5079 I/O
Tower" on
page 747.
"Locations —
Table 41 on page 710.
Models 830,
SB2 System
Unit with FC
9074 Base I/O
Tower" on
page 709.
Figure 36 on
Table 43 on page 725.
page 724.
603