IBM i 830 Repair Manual page 211

Table of Contents

Advertisement

Reference Code
Description/Action Perform all actions before exchanging Failing Items
0103
WS IOP detected parity error from device
Is the problem intermittent?
No
Perform "TWSC-PIP1" on page 465.
0104
Device detected parity error from WS IOP
Is the problem intermittent?
No
Perform "TWSC-PIP1" on page 465.
0105
WS IOP detected error when transmitting data
Is the problem intermittent?
No
Perform "TWSC-PIP1" on page 465.
0106
WS IOP detected wrong data from device
Is the problem intermittent?
No
Perform "TWSC-PIP1" on page 465.
0107
WS IOP detected wrong address from device
Is the problem intermittent?
No
Perform "TWSC-PIP1" on page 465.
0108
WS IOP detected device power turned off, and then on
Perform "TWSC-PIP1" on page 465.
Yes
Perform the following procedures:
1. "INT-PIP5 External Noise on Twinaxial Cables" on page 333
2. "INT-PIP14 Station Protectors" on page 339
Yes
Perform the following procedures:
1. "INT-PIP5 External Noise on Twinaxial Cables" on page 333
2. "INT-PIP14 Station Protectors" on page 339
Yes
Perform the following procedures:
1. "INT-PIP5 External Noise on Twinaxial Cables" on page 333
2. "INT-PIP14 Station Protectors" on page 339
Yes
Perform the following procedures:
1. "INT-PIP5 External Noise on Twinaxial Cables" on page 333
2. "INT-PIP14 Station Protectors" on page 339
Yes
Perform the following procedures:
1. "INT-PIP5 External Noise on Twinaxial Cables" on page 333
2. "INT-PIP14 Station Protectors" on page 339
Failing Item
FI00602
FI00601
GAU7777
FI00610
FI00602
FI00601
GAU7777
FI00610
FI00602
FI00601
GAU8888
FI00610
FI00615
FI00601
FI00602
GAU8888
FI00610
FI00601
GAU8888
GAU7777
FI00610
GAUEEEE
FI00601
Chapter 2. Unit Reference Codes
B070
197

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

I sb3I 840I sb2

Table of Contents